Assessment Year | 2005 |
---|---|
Principal Product | Carbon and Alloy Steel Forgings |
NAICS | 332111: Iron and Steel Forging |
SIC | 3462: Iron and Steel Forgings |
Sales Range | $10 M to 50M |
# of Employees | 52 |
Plant Area |
89,800
ft2
|
Annual Production | 37,804,000
lb
|
Production Hrs. Annual | 5,610
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $484,999 | 6,229,305 |
kWh
|
$0.078 |
Electricity Fees | $2,271 | - |
|
- |
Natural Gas | $91,099 | 12,437 |
MMBtu
|
$7.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,256 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,242 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $42,936 | $135,000 |
$42,936
550,473
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $5,622 | $2,000 | - |
$5,622
-
MMBtu
|
|
03 | 2.7124: Make a practice of turning off lights when not needed | $3,242 | - |
$3,242
41,561
kWh
|
- | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $2,966 | $200 |
$2,966
38,031
kWh
|
- | |
05 | 2.7243: Improve air circulation with destratification fans / other methods | $1,699 | $700 | - |
$1,699
-
MMBtu
|
|
06 | 2.4239: Eliminate or reduce compressed air usage | $791 | $2,000 | - |
$791
-
MMBtu
|
|
TOTAL RECOMMENDED | $57,256 | $139,900 |
$49,144
630,065
kWh
|
$8,112
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,242 | - |
$3,242
41,561
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs