Assessment Year | 1996 |
---|---|
Principal Product | Steel, Cold Roll Sheet, Strip and Bars |
NAICS |
n/a
|
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
196,000
ft2
|
Annual Production | 95,000
ton
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $467,616 | 5,949,004 |
kWh
|
$0.079 |
Electricity Demand | $291,563 | 17,328 |
kW-mo/yr
|
$16.83 |
Electricity Fees | $(-281.0) | - |
|
- |
Natural Gas | $63,789 | 17,004 |
MMBtu
|
$3.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,369 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $557 | $400 | n/a |
$388
7,327
kWh
|
$169
-
kW-mo/yr
|
- | - |
02 | 2.3212: Optimize plant power factor | $13,487 | $7,548 | n/a | - |
$13,487
-
kW-mo/yr
|
- | - |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,967 | $4,130 | n/a |
$2,870
22,567
kWh
|
$1,097
-
kW-mo/yr
|
- | - |
04 | 2.4221: Install compressor air intakes in coolest locations | $5,525 | $1,000 | n/a |
$3,843
72,392
kWh
|
$1,682
-
kW-mo/yr
|
- | - |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $413 | $2,025 | n/a | - | - |
$413
-
MMBtu
|
- |
06 | 3.1191: Change procedures / equipment / operating conditions | $3,420 | $852 | n/a | - | - | - |
$3,420
-
lb
|
TOTAL RECOMMENDED | $27,369 | $15,955 |
$7,101
102,286
kWh
|
$16,435
-
kW-mo/yr
|
$413
-
MMBtu
|
$3,420
-
lb
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs