| Assessment Year | 1996 |
|---|---|
| Principal Product | Metal Stampings and Assemblies |
| NAICS |
n/a
|
| SIC | 3469: Metal Stampings, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 294 |
| Plant Area |
120,000
ft2
|
| Annual Production | 30,000
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $233,042 | 6,570,047 |
kWh
|
$0.035 |
| Electricity Demand | $16,669 | 14,526 |
kW-mo/yr
|
$1.15 |
| Electricity Fees | $(-7,352.0) | - |
|
- |
| Natural Gas | $38,265 | 7,952 |
MMBtu
|
$4.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $33,361 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $5,129 | $17,603 | - |
$5,129
-
kW-mo/yr
|
- | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $2,553 | $4,800 |
$2,017
34,291
kWh
|
$536
-
kW-mo/yr
|
- | - | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $9,921 | $4,266 | - | - |
$9,921
-
MMBtu
|
- | |
| 04 | 2.7243: Improve air circulation with destratification fans / other methods | $4,733 | $18,000 | - | - |
$4,733
-
MMBtu
|
- | |
| 05 | 3.2111: Install redundant equipment to avoid losses caused by equipment failure and routine maintenance | $11,025 | $680 | - | - | - |
$11,025
-
gal
|
|
| TOTAL RECOMMENDED | $33,361 | $45,349 |
$2,017
34,291
kWh
|
$5,665
-
kW-mo/yr
|
$14,654
-
MMBtu
|
$11,025
-
gal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs