Assessment Year | 1998 |
---|---|
Principal Product | isolated soy protein |
NAICS |
n/a
|
SIC | 2075: Soybean Oil Mills |
Sales Range | $10 M to 50M |
# of Employees | 96 |
Plant Area |
113,000
ft2
|
Annual Production | 45,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $667,544 | 26,655,335 |
kWh
|
$0.025 |
Electricity Demand | $351,329 | 100,224 |
kW-mo/yr
|
$3.51 |
Natural Gas | $1,795,015 | 457,045 |
MMBtu
|
$3.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,890,868 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $177,628 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Water Consumption Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,850 | $20 |
$6,541
261,137
kWh
|
$1,309
-
kW-mo/yr
|
- | - | - | - | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $4,732 | $260 |
$3,942
157,386
kWh
|
$790
-
kW-mo/yr
|
- | - | - | - | - | - | |
03 | 2.7261: Install timers and/or thermostats | $6,368 | $800 | - | - |
$6,368
-
MMBtu
|
- | - | - | - | - | |
04 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $2,628 | - | - | - | - | - |
$2,628
-
lb
|
- | - | - | |
05 | 3.3128: Utilize other methods to remove contaminants | $6,458,418 | $3,180,000 | - | - |
$1,094,959
-
MMBtu
|
$5,363,459
-
Tgal
|
- | - | - | - | |
06 | 3.4151: Minimize water usage | $235,872 | $666,500 | - | - | - |
$151,956
-
Tgal
|
- | - |
$83,916
-
Tgal
|
- | |
07 | 4.624: Hire additional personnel to reduce changeout time | $70,000 | - | - | - | - | - | - | $70,000 | - | - | |
08 | 4.512: Condense operation into one building | $105,000 | $300,000 | - | - | - | - | - | - | - | $105,000 | |
TOTAL RECOMMENDED | $6,890,868 | $4,147,580 |
$10,483
418,523
kWh
|
$2,099
-
kW-mo/yr
|
$1,101,327
-
MMBtu
|
$5,515,415
-
Tgal
|
$2,628
-
lb
|
$70,000 |
$83,916
-
Tgal
|
$105,000 | ||
TOTAL IMPLEMENTED | $177,628 | $300,000 | - | - | - | - |
$2,628
-
lb
|
$70,000 | - | $105,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Water Consumption Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs