Assessment Year | 1996 |
---|---|
Principal Product | Tortillas and Chips |
NAICS |
n/a
|
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 360 |
Plant Area |
134,200
ft2
|
Annual Production | 4,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $151,479 | 6,332,063 |
kWh
|
$0.024 |
Electricity Demand | $120,782 | 13,201 |
kW-mo/yr
|
$9.15 |
Natural Gas | $207,606 | 55,110 |
MMBtu
|
$3.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $202,266 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $192,762 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $104 | $1,770 |
$60
2,638
kWh
|
$44
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,326 | $130 |
$764
31,946
kWh
|
$562
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7261: Install timers and/or thermostats | $775 | $200 | - | - |
$775
-
MMBtu
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,217 | $7,907 |
$779
32,532
kWh
|
$438
-
kW-mo/yr
|
- | - | - | - | |
05 | 3.1191: Change procedures / equipment / operating conditions | $4,527 | - | - | - | - | - |
$2,751
-
lb
|
$1,776 | |
06 | 3.5313: Increase amount of waste recovered for resale | $2,010 | $250 | - | - | - | - |
$2,010
-
lb
|
- | |
07 | 3.5313: Increase amount of waste recovered for resale | $975 | $300 | - | - | - | - |
$975
-
lb
|
- | |
08 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $191,332 | $265,000 | - | - | - |
$16,332
-
Tgal
|
- | $175,000 | |
TOTAL RECOMMENDED | $202,266 | $275,557 |
$1,603
67,116
kWh
|
$1,044
-
kW-mo/yr
|
$775
-
MMBtu
|
$16,332
-
Tgal
|
$5,736
-
lb
|
$176,776 | ||
TOTAL IMPLEMENTED | $192,762 | $266,900 |
$824
34,584
kWh
|
$606
-
kW-mo/yr
|
- |
$16,332
-
Tgal
|
- | $175,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs