Assessment Year | 2014 |
---|---|
Principal Product | cement |
NAICS | 327310: Cement Manufacturing |
SIC | 3241: Cement, Hydraulic |
Sales Range | $50 M to 100M |
# of Employees | 87 |
Plant Area |
487,500
ft2
|
Annual Production | 1,000,000
ton
|
Production Hrs. Annual | 6,096
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $5,492,559 | 102,574,104 |
kWh
|
$0.054 |
Electricity Demand | $996,893 | 242,892 |
kW-mo/yr
|
$4.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $142,601 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,346 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $118,558 | $160,800 |
$104,377
1,949,269
kWh
|
$14,181
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,697 | $549 |
$5,697
106,430
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,346 | $7,195 | - | - | $18,346 | |
TOTAL RECOMMENDED | $142,601 | $168,544 |
$110,074
2,055,699
kWh
|
$14,181
-
kW-mo/yr
|
$18,346 | ||
TOTAL IMPLEMENTED | $18,346 | $7,195 | - | - | $18,346 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs