| Assessment Year | 2026 |
|---|---|
| Principal Product | Sheet Metal Enclosures |
| NAICS | 332322: Sheet Metal Work Manufacturing |
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 160 |
| Plant Area |
240,000
ft2
|
| Annual Production | 10,000
units
|
| Production Hrs. Annual | 2,375
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $144,265 | 2,308,157 |
kWh
|
$0.063 |
| Electricity Demand | $130,444 | 9,465 |
kW-mo/yr
|
$13.78 |
| Electricity Fees | $49,862 | - |
|
- |
| Natural Gas | $122,970 | 8,457 |
MMBtu
|
$14.54 |
| TOTAL YEARLY COSTS | $447,541 | |||
| RECOMMENDED SAVINGS* | $432,364 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $75,479 | $250,000 |
$9,727
154,404
kWh
|
$10,752
-
kW-mo/yr
|
- | $55,000 | - | - | |
| 02 | 2.3191: Use demand controller or load shedder | $19,310 | $12,418 |
$10,179
161,571
kWh
|
$9,131
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7446: Utilize sensors controlling roof and wall openings | $8,168 | $4,000 |
$959
15,221
kWh
|
$1,060
-
kW-mo/yr
|
$6,149
-
MMBtu
|
- | - | - | |
| 04 | 2.2522: Isolate hot or cold equipment | $7,455 | $28,000 |
$4,455
70,708
kWh
|
- | - | - | $3,000 | - | |
| 05 | 2.2623: Minimize condenser cooling water temperature | $1,056 | $2,800 |
$1,056
16,754
kWh
|
- | - | - | - | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $442 | - |
$234
3,710
kWh
|
- | - | $99 | - | $109 | |
| 07 | 2.4131: Size electric motors for peak operating efficiency | $377 | - |
$377
5,980
kWh
|
- | - | - | - | - | |
| 08 | 2.4237: Substitute compressed air cooling with water or air cooling | $369 | $900 |
$369
5,864
kWh
|
- | - | - | - | - | |
| 09 | 4.446: Automate finishing process | $242,080 | $200,000 |
$1,822
28,925
kWh
|
$2,658
-
kW-mo/yr
|
- | $237,600 | - | - | |
| 10 | 4.126: Install sensors to detect defects | $50,000 | $85,000 | - | - | - | $44,000 | $6,000 | - | |
| 11 | 4.321: Optimize production lot sizes and inventories | $22,000 | $4,000 | - | - | - | $22,000 | - | - | |
| 12 | 4.513: Re-arrange equipment layout to reduce labor costs | $5,628 | $1,368 | - | - | - | $2,931 | $2,697 | - | |
| TOTAL RECOMMENDED | $432,364 | $588,486 |
$29,178
463,137
kWh
|
$23,601
-
kW-mo/yr
|
$6,149
-
MMBtu
|
$361,630 | $11,697 | $109 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs