ITAC Assessment: NL0078
ITAC logo
ITAC Assessment: NL0078
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Rubber O-Rings
NAICS 326291: Rubber Product Manufacturing for Mechanical Use
SIC 3061: Molded, Extruded, and Lathe-Cut Mechanical Rubber Goods
Sales Range $5
M
to 10
M
# of Employees 43
Plant Area 75,350
ft2
Annual Production 130,000,000
units
Production Hrs. Annual 6,000
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $140,151 3,027,750
kWh
Electricity Demand $153,153 9,850
kW-mo/yr
Waste Disposal Costs
Water Usage $5,115 3,616
Tgal
Water Disposal $3,027 3,616
Tgal
TOTAL YEARLY COSTS $301,446
RECOMMENDED SAVINGS* $51,708 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $45,158

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings Increase in Production Savings
01 2.1243: Use heat from boiler blowdown to preheat boiler feed water $31,345 $100,000 $31,345
677,005
kWh
- - - - -
02 2.7243: Improve air circulation with destratification fans / other methods $10,358 $17,280 $1,347
29,290
kWh
$911
-
kW-mo/yr
- - - $8,100
03 2.4224: Upgrade controls on compressors $6,550 $20,000 $6,550
141,473
kWh
- - - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,587 $2,300 $2,967
64,076
kWh
- - $(-1,280.0) $(-100.0) -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $812 $2,080 $812
17,540
kWh
- - - - -
06 2.7221: Lower temperature during the winter season and vice-versa $658 $80 $658
14,301
kWh
- - - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $270 $415 $49
1,052
kWh
$22
-
kW-mo/yr
- $199 - -
08 3.4155: Meter waste water $128 $250 - - $406
-
Tgal
- $(-278.0) -
TOTAL RECOMMENDED $51,708 $142,405 $43,728
944,737
kWh
$933
-
kW-mo/yr
$406
-
Tgal
$(-1,081.0) $(-378.0) $8,100
TOTAL IMPLEMENTED $45,158 $122,405 $37,178
803,264
kWh
$933
-
kW-mo/yr
$406
-
Tgal
$(-1,081.0) $(-378.0) $8,100
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs