| Assessment Year | 2025 |
|---|---|
| Principal Product | Turbine Components |
| NAICS | 333611: Turbine and Turbine Generator Set Units Manufacturing |
| SIC | 3511: Steam, Gas, and Hydraulic Turbines, and Turbine Generator Set Units |
| Sales Range | $10 M to 50M |
| # of Employees | 280 |
| Plant Area |
155,000
ft2
|
| Annual Production | 120,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $976,766 | 21,371,598 |
kWh
|
$0.046 | |
| Electricity Demand | $936,278 | 45,347 |
kW-mo/yr
|
$20.65 | |
| Electricity Fees | $57,503 | - |
|
- | |
| Natural Gas | $384,241 | 41,889 |
MMBtu
|
$9.17 | |
| Waste Disposal Costs | |||||
| Water Usage | $40,661 | 3,798 |
Tgal
|
$10.71 | |
| TOTAL YEARLY COSTS | $2,395,449 | ||||
| RECOMMENDED SAVINGS* | $449,122 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $134,351 | $114,981 |
$68,817
1,496,012
kWh
|
$65,534
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.9114: Use solar heat to make electricty | $50,327 | $322,608 |
$30,506
663,164
kWh
|
$19,821
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $24,548 | $21,000 |
$6,484
140,952
kWh
|
$18,064
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $15,162 | $60,000 |
$(-13,000.0)
(-282,609)
kWh
|
$(-31,838.0)
-
kW-mo/yr
|
- | - | $60,000 | |
| 05 | 2.6231: Utilize controls to operate equipment only when needed | $10,233 | $25,500 |
$10,233
222,452
kWh
|
- | - | - | - | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $9,314 | $12,000 | - | - |
$9,314
-
MMBtu
|
- | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,448 | $469 |
$4,448
96,682
kWh
|
- | - | - | - | |
| 08 | 2.4224: Upgrade controls on compressors | $1,111 | $208 |
$1,111
24,148
kWh
|
- | - | - | - | |
| 09 | 3.5222: Use sand for other purposes (eg construction fill, cover for municipal landfills) | $5,400 | $1,000 | - | - | - | - | $5,400 | |
| 10 | 4.424: Improve space comfort conditioning | $141,728 | $22,650 |
$(-1,261.0)
(-27,404)
kWh
|
$(-2,611.0)
-
kW-mo/yr
|
- | $145,600 | - | |
| 11 | 4.652: Replace existing equipment with more suitable substitutes | $52,500 | $4,200 | - | - | - | $52,500 | - | |
| TOTAL RECOMMENDED | $449,122 | $584,616 |
$107,338
2,333,397
kWh
|
$68,970
-
kW-mo/yr
|
$9,314
-
MMBtu
|
$198,100 | $65,400 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs