| Assessment Year | 2025 |
|---|---|
| Principal Product | Optical Componenents |
| NAICS | 333314: Optical Instrument and Lens Manufacturing |
| SIC | 3827: Optical Instruments and Lenses |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
41,000
ft2
|
| Annual Production | 1,000,000
units
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $232,673 | 2,669,047 |
kWh
|
$0.087 |
| Electricity Demand | $66,485 | 12,548 |
kW-mo/yr
|
$5.30 |
| Electricity Fees | $32,939 | - |
|
- |
| TOTAL YEARLY COSTS | $332,097 | |||
| RECOMMENDED SAVINGS* | $179,034 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $96,653 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $59,131 | $322,608 |
$54,045
621,206
kWh
|
$5,086
-
kW-mo/yr
|
- | |
| 02 | 2.3192: Use fossil fuel powered generator during peak demand periods | $20,908 | $14,359 |
$16,254
186,833
kWh
|
$4,654
-
kW-mo/yr
|
- | |
| 03 | 2.3141: Use battery storage for demand control | $11,217 | $21,658 |
$783
9,000
kWh
|
- | $10,434 | |
| 04 | 2.6231: Utilize controls to operate equipment only when needed | $12,033 | $25,340 |
$12,033
138,317
kWh
|
- | - | |
| 05 | 2.4239: Eliminate or reduce compressed air usage | $8,280 | - |
$8,280
95,171
kWh
|
- | - | |
| 06 | 2.4224: Upgrade controls on compressors | $5,844 | $6,000 |
$5,844
67,177
kWh
|
- | - | |
| 07 | 4.112: Replace old machine with new automatic multi-station tool | $38,400 | $100,000 | - | - | $38,400 | |
| 08 | 4.661: Level zero – install control systems for existing equipment | $23,221 | $60,000 |
$23,221
266,905
kWh
|
- | - | |
| TOTAL RECOMMENDED | $179,034 | $549,965 |
$120,460
1,384,609
kWh
|
$9,740
-
kW-mo/yr
|
$48,834 | ||
| TOTAL IMPLEMENTED | $96,653 | $180,359 |
$53,599
616,086
kWh
|
$4,654
-
kW-mo/yr
|
$38,400 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs