ITAC Assessment: UF0616
ITAC logo
ITAC Assessment: UF0616
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Radiation Therapy Devices
NAICS 339113: Surgical Appliance and Supplies Manufacturing
SIC 3841: Surgical and Medical Instruments and Apparatus
Sales Range $5
M
to 10
M
# of Employees 30
Plant Area 35,000
ft2
Annual Production 484,773
units
Production Hrs. Annual 4,940
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $73,908 1,087,200
kWh
Electricity Demand $34,191 2,685
kW-mo/yr
Electricity Fees $18,889 -
TOTAL YEARLY COSTS $126,988
RECOMMENDED SAVINGS* $121,814 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.9114: Use solar heat to make electricty $80,652 $322,608 $43,978
646,737
kWh
$36,674
-
kW-mo/yr
- - -
02 2.7243: Improve air circulation with destratification fans / other methods $21,638 $12,552 $(-248.0)
(-3,650)
kWh
$(-536.0)
-
kW-mo/yr
- $22,422 -
03 2.3191: Use demand controller or load shedder $7,571 $5,849 $5,175
76,104
kWh
$2,396
-
kW-mo/yr
- - -
04 2.6231: Utilize controls to operate equipment only when needed $5,125 $25,440 $2,793
41,076
kWh
$2,332
-
kW-mo/yr
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,749 $327 $1,749
25,723
kWh
- - - -
06 2.6231: Utilize controls to operate equipment only when needed $1,368 $202 $1,368
20,123
kWh
- - - -
07 2.7421: Reduce glazed areas in buildings $1,097 $1,075 $1,097
16,129
kWh
- - - -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,073 - $644
9,467
kWh
- $248 - $181
09 2.4239: Eliminate or reduce compressed air usage $1,015 - $1,015
14,925
kWh
- - - -
10 2.4224: Upgrade controls on compressors $526 $1,500 $526
7,739
kWh
- - - -
TOTAL RECOMMENDED $121,814 $369,553 $58,097
854,373
kWh
$40,866
-
kW-mo/yr
$248 $22,422 $181
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs