| Assessment Year | 2011 |
|---|---|
| Principal Product | Flat Glass |
| NAICS | 327211: Flat Glass Manufacturing |
| SIC | 3211: Flat Glass |
| Sales Range | $10 M to 50M |
| # of Employees | 34 |
| Plant Area |
77,768
ft2
|
| Annual Production | 800,000
pieces
|
| Production Hrs. Annual | 5,460
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $66,256 | 686,200 |
kWh
|
$0.097 |
| Electricity Demand | $39,659 | 4,892 |
kW-mo/yr
|
$8.11 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,262 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7124: Make a practice of turning off lights when not needed | $366 | - |
$366
3,691
kWh
|
- | |
| 02 | 2.7145: Install skylights | $1,404 | $3,128 |
$1,404
14,180
kWh
|
- | |
| 03 | 2.2511: Insulate bare equipment | $527 | $33 |
$527
3,355
kWh
|
- | |
| 04 | 2.7495: Install replacement doors | $588 | $1,150 |
$588
3,742
kWh
|
- | |
| 05 | 2.7261: Install timers and/or thermostats | $1,489 | $1,079 |
$1,489
15,040
kWh
|
- | |
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $168 | $172 |
$168
1,700
kWh
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,230 | $685 |
$2,230
14,297
kWh
|
- | |
| 08 | 2.6218: Turn off equipment when not in use | $2,229 | - |
$2,229
23,521
kWh
|
- | |
| 09 | 2.4224: Upgrade controls on compressors | $648 | $410 |
$648
4,127
kWh
|
- | |
| 10 | 2.8121: Apply for tax-free status for energy purchases | $15,613 | - | - | $15,613 | |
| TOTAL RECOMMENDED | $25,262 | $6,657 |
$9,649
83,653
kWh
|
$15,613 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs