Assessment Year | 2010 |
---|---|
Principal Product | Mrhyl Ester |
NAICS | 325199: All Other Basic Organic Chemical Manufacturing |
SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 14 |
Plant Area |
22,000
ft2
|
Annual Production | 19,000
Tgal
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $180,617 | 2,045,888 |
kWh
|
$0.088 |
Electricity Demand | $36,740 | 4,584 |
kW-mo/yr
|
$8.01 |
Electricity Fees | $28,122 | - |
|
- |
Natural Gas | $101,961 | 14,471 |
MMBtu
|
$7.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $78,806 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $33,739 | $32,047 |
$33,434
334,150
kWh
|
$305
-
kW-mo/yr
|
- | - | |
02 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $4,188 | $5,591 | - | - |
$4,188
-
MMBtu
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $14,940 | $2,240 |
$14,735
140,758
kWh
|
$205
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,539 | $719 |
$1,539
17,095
kWh
|
- | - | - | |
05 | 2.7134: Use photocell controls | $6,416 | $768 |
$6,416
59,405
kWh
|
- | - | - | |
06 | 2.4225: Install common header on compressors | $1,520 | - |
$1,520
14,079
kWh
|
- | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,000 | $2,700 |
$3,000
27,781
kWh
|
- | - | - | |
08 | 2.4151: Develop a repair/replace policy | $364 | - |
$364
4,013
kWh
|
- | - | - | |
09 | 2.2615: Clean condenser tubes | $1,343 | $120 |
$1,343
12,438
kWh
|
- | - | - | |
10 | 2.4156: Establish a preventative maintenance program | $3,120 | - | - | - | - | $3,120 | |
11 | 2.4221: Install compressor air intakes in coolest locations | $8,637 | $1,500 |
$8,637
95,966
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $78,806 | $45,685 |
$70,988
705,685
kWh
|
$510
-
kW-mo/yr
|
$4,188
-
MMBtu
|
$3,120 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs