| Assessment Year | 2009 |
|---|---|
| Principal Product | Dimensioned Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
177,000
ft2
|
| Annual Production | 180,000,000
units
|
| Production Hrs. Annual | 2,704
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $867,717 | 11,797,340 |
kWh
|
$0.074 |
| Fuel Oil #1 | $121,727 | 4,140 |
MMBtu
|
$29.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $151,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #1 Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $53,117 | $28,843 |
$53,117
717,791
kWh
|
- | - | - | |
| 02 | 2.7135: Install occupancy sensors | $151 | $562 |
$151
2,047
kWh
|
- | - | - | |
| 03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $11,733 | $397 |
$11,733
158,558
kWh
|
- | - | - | |
| 04 | 2.6231: Utilize controls to operate equipment only when needed | $2,063 | $425 |
$2,063
27,875
kWh
|
- | - | - | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $31,025 | $24,740 | - | - | $31,025 | - | |
| 06 | 2.7423: Reduce heat gain by window tinting | $790 | $800 |
$790
10,680
kWh
|
- | - | - | |
| 07 | 3.5313: Increase amount of waste recovered for resale | $512 | $2,500 | - | - | - | $512 | |
| 08 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $1,080 | $512 |
$48
646
kWh
|
- | $1,032 | - | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,732 | $564 |
$1,732
23,409
kWh
|
- | - | - | |
| 10 | 2.4239: Eliminate or reduce compressed air usage | $9,752 | $300 |
$9,752
131,789
kWh
|
- | - | - | |
| 11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,525 | - |
$2,525
34,124
kWh
|
- | - | - | |
| 12 | 2.4224: Upgrade controls on compressors | $6,440 | $6,884 |
$6,440
87,033
kWh
|
- | - | - | |
| 13 | 2.4224: Upgrade controls on compressors | $14,512 | $12,272 |
$14,512
196,115
kWh
|
- | - | - | |
| 14 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $13,923 | - | - |
$13,923
-
MMBtu
|
- | - | |
| 15 | 2.6125: Keep equipment clean | $1,885 | $816 |
$1,885
25,480
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $151,240 | $79,615 |
$104,748
1,415,547
kWh
|
$13,923
-
MMBtu
|
$32,057 | $512 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #1 Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs