Assessment Year 2008
Principal Product Magazines
NAICS 323117: Books Printing
SIC 2732: Book Printing
Sales Range $10
M
to 50
M
# of Employees 225
Plant Area 85,000
ft2
Annual Production 300,000,000
pieces
Production Hrs. Annual 7,488
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $568,022 7,743,600
kWh
Electricity Demand $57,282 15,474
kW-mo/yr
Electricity Fees $305 -
Natural Gas $132,408 9,025
MMBtu
Other Gas $59,623 3,495
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $252,128 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $106,320

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Primary Raw Material Savings
01 2.7243: Improve air circulation with destratification fans / other methods $11,798 $16,755 $11,798
161,615
kWh
- - - -
02 2.7261: Install timers and/or thermostats $8,549 $1,248 $8,549
117,109
kWh
- - - -
03 2.7444: Close holes and openings in building such as broken windows $349 $29 $349
4,780
kWh
- - - -
04 2.2531: Re-size charging openings or add movable cover or door $2,156 $20,960 $2,156
26,242
kWh
- - - -
05 2.2511: Insulate bare equipment $764 $2,390 - - $764
-
MMBtu
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $48,158 $1,870 $48,158
594,538
kWh
- - - -
07 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $22,082 $24,230 $22,082
272,613
kWh
- - - -
08 2.4133: Use most efficient type of electric motors $3,400 $10,830 $3,027
41,444
kWh
$373
-
kW-mo/yr
- - -
09 2.7226: Use computer programs to optimize hvac performance $17,491 $25,340 $17,491
239,596
kWh
- - - -
10 2.7141: Lower light fixtures in high ceiling areas $2,511 $406 $2,347
32,148
kWh
$164
-
kW-mo/yr
- - -
11 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,589 $794 $1,589
21,767
kWh
- - - -
12 2.7142: Utilize higher efficiency lamps and/or ballasts $8,401 $10,282 $7,823
110,685
kWh
$578
-
kW-mo/yr
- - -
13 2.7135: Install occupancy sensors $1,180 $162 $1,180
16,175
kWh
- - - -
14 4.651: Install back-up equipment $76,789 $12,000 - - - - $76,789
15 3.5217: Reuse / recycle/ sell paper products $46,911 - - - - $46,911 -
TOTAL RECOMMENDED $252,128 $127,296 $126,549
1,638,712
kWh
$1,115
-
kW-mo/yr
$764
-
MMBtu
$46,911 $76,789
TOTAL IMPLEMENTED $106,320 $6,331 $58,645
738,194
kWh
- $764
-
MMBtu
$46,911 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs