Assessment Year 2004
Principal Product Weekly Publications
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 230
Plant Area 69,000
ft2
Annual Production 42,640,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $131,633 2,638,262
kWh
Electricity Demand $42,504 6,198
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,289 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,307

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings Primary Product Savings
01 2.6125: Keep equipment clean $1,555 $432 $1,555
29,912
kWh
- - - -
02 2.7131: Add area lighting switches $8,786 $400 $8,786
127,332
kWh
- - - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,468 - $1,468
21,273
kWh
- - - -
04 2.7135: Install occupancy sensors $1,509 $1,035 $1,509
21,869
kWh
- - - -
05 4.111: Add equipment/ operators to reduce production bottleneck $1,651 $5,000 $699
13,441
kWh
$952
-
kW-mo/yr
- - -
06 2.7447: Install vinyl strip / high speed / air curtain doors $3,482 $252 $3,482
50,471
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,554 $5,600 $2,103
40,443
kWh
$451
-
kW-mo/yr
- - -
08 2.4151: Develop a repair/replace policy $1,159 $5,189 $835
16,049
kWh
$324
-
kW-mo/yr
- - -
09 2.8112: Combine utility meters $1,189 - - - $1,189 - -
10 3.4155: Meter waste water $1,036 $940 - - - $1,036
-
Tgal
-
11 4.711: Initiate a total quality management program $8,900 $2,070 - - - - $8,900
TOTAL RECOMMENDED $33,289 $20,918 $20,437
320,790
kWh
$1,727
-
kW-mo/yr
$1,189 $1,036
-
Tgal
$8,900
TOTAL IMPLEMENTED $20,307 $13,543 $9,443
158,148
kWh
$775
-
kW-mo/yr
$1,189 - $8,900
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs