ITAC Assessment: UF0312
ITAC logo
ITAC Assessment: UF0312
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product Newspapers and other publications
NAICS
n/a
SIC 2711: Newspapers: Publishing, or Publishing and Printing
Sales Range $10
M
to 50
M
# of Employees 270
Plant Area 65,119
ft2
Annual Production 8,600,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $225,410 3,686,880
kWh
Electricity Demand $37,112 7,429
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,312 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,720

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 4.652: Replace existing equipment with more suitable substitutes $6,162 $7,981 $5,394
88,420
kWh
$768
-
kW-mo/yr
02 2.7135: Install occupancy sensors $1,258 $6,000 $1,258
17,976
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,934 $500 $1,934
27,671
kWh
-
04 2.6231: Utilize controls to operate equipment only when needed $10,427 $20,000 $8,369
137,200
kWh
$2,058
-
kW-mo/yr
05 2.7491: Insulate glazing, walls, ceilings, and roofs $38,400 $31,277 $38,400
548,572
kWh
-
06 2.7447: Install vinyl strip / high speed / air curtain doors $7,131 $1,074 $7,131
101,868
kWh
-
TOTAL RECOMMENDED $65,312 $66,832 $62,486
921,707
kWh
$2,826
-
kW-mo/yr
TOTAL IMPLEMENTED $23,720 $29,055 $20,894
327,488
kWh
$2,826
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs