Assessment Year | 1996 |
---|---|
Principal Product | air shafts and chucks |
NAICS |
n/a
|
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
56,000
ft2
|
Annual Production | 900,000
lb
|
Production Hrs. Annual | 4,224
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,092 | 990,914 |
kWh
|
$0.023 |
Electricity Demand | $7,613 | 3,360 |
kW-mo/yr
|
$2.27 |
Natural Gas | $18,908 | 3,715 |
MMBtu
|
$5.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,997 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,203 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2515: Use optimum thickness insulation | $12,794 | $20,784 | - | - |
$12,794
-
MMBtu
|
- | - | |
02 | 3.3133: Use other waste concentration methods | $5,324 | $10,000 | - | - | - |
$6,124
-
gal
|
$(-800.0) | |
03 | 2.4224: Upgrade controls on compressors | $952 | $3,840 |
$485
25,205
kWh
|
$467
-
kW-mo/yr
|
- | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $927 | $4,907 |
$501
26,084
kWh
|
$426
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $19,997 | $39,531 |
$986
51,289
kWh
|
$893
-
kW-mo/yr
|
$12,794
-
MMBtu
|
$6,124
-
gal
|
$(-800.0) | ||
TOTAL IMPLEMENTED | $7,203 | $18,747 |
$986
51,289
kWh
|
$893
-
kW-mo/yr
|
- |
$6,124
-
gal
|
$(-800.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs