Assessment Year | 1993 |
---|---|
Principal Product | Boats |
NAICS |
n/a
|
SIC | 3731: Ship Building and Repairing |
Sales Range | $10 M to 50M |
# of Employees | 550 |
Plant Area |
500,000
ft2
|
Annual Production | 3,500
pieces
|
Production Hrs. Annual | 3,640
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $337,856 | 5,614,009 |
kWh
|
$0.060 |
Natural Gas | $868 | 127 |
MMBtu
|
$6.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $116,911 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,359 | $5,917 |
$6,359
106,096
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,652 | $5,262 |
$1,652
27,550
kWh
|
|
03 | 2.6231: Utilize controls to operate equipment only when needed | $11,110 | $13,200 |
$11,110
185,229
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $180 | $306 |
$180
2,931
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $260 | $480 |
$260
4,396
kWh
|
|
06 | 2.4133: Use most efficient type of electric motors | $2,939 | $25,197 |
$2,939
48,945
kWh
|
|
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,616 | $2,550 |
$1,616
26,964
kWh
|
|
08 | 2.6127: Maintain air filters by cleaning or replacement | $13,151 | $2,000 |
$13,151
219,226
kWh
|
|
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,546 | $2,000 |
$5,546
92,321
kWh
|
|
10 | 2.6231: Utilize controls to operate equipment only when needed | $3,712 | $1,000 |
$3,712
31,946
kWh
|
|
11 | 2.7232: Replace existing hvac unit with high efficiency model | $3,659 | $2,850 |
$3,659
60,961
kWh
|
|
12 | 2.7261: Install timers and/or thermostats | $1,081 | $1,300 |
$1,081
17,878
kWh
|
|
13 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,265 | - |
$2,265
-
kWh
|
|
14 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $1,560 | $1,400 |
$1,560
26,084
kWh
|
|
15 | 2.6242: Minimize operation of equipment maintained in standby condition | $61,821 | $250,000 |
$61,821
-
kWh
|
|
TOTAL RECOMMENDED | $116,911 | $313,462 |
$116,911
850,527
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs