Assessment Year | 2025 |
---|---|
Principal Product | Fabricated Metal |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
70,000
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 2,483
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $81,232 | 609,211 |
kWh
|
$0.13 | |
Electricity Demand | $16,861 | 2,405 |
kW-mo/yr
|
$7.01 | |
Electricity Fees | $1,999 | - |
|
- | |
Natural Gas | $22,690 | 5,203 |
MMBtu
|
$4.36 | |
Waste Disposal Costs | |||||
Water Usage | $1,045 | 224 |
Tgal
|
$4.67 | |
Water Disposal | $1,137 | 224 |
Tgal
|
$5.08 | |
TOTAL YEARLY COSTS | $124,964 | ||||
RECOMMENDED SAVINGS* | $23,349 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $1,791 | - |
$1,286
9,648
kWh
|
$505
-
kW-mo/yr
|
- | - | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $9,462 | $15,035 |
$9,462
70,986
kWh
|
- | - | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,126 | $5,813 |
$3,250
24,379
kWh
|
$876
-
kW-mo/yr
|
- | - | |
04 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $2,842 | $908 |
$652
4,888
kWh
|
- | - |
$2,190
-
MMBtu
|
|
05 | 2.6231: Utilize controls to operate equipment only when needed | $251 | - |
$251
1,880
kWh
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,166 | $5,318 |
$1,727
12,952
kWh
|
$439
-
kW-mo/yr
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $712 | $1,015 |
$559
4,194
kWh
|
$153
-
kW-mo/yr
|
- | - | |
08 | 2.3212: Optimize plant power factor | $1,999 | $5,700 | - | - | $1,999 | - | |
TOTAL RECOMMENDED | $23,349 | $33,789 |
$17,187
128,927
kWh
|
$1,973
-
kW-mo/yr
|
$1,999 |
$2,190
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs