ITAC Assessment: UD1034
ITAC logo
ITAC Assessment: UD1034
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Travel Trailers and Motor Homes
NAICS 336214: Travel Trailer and Camper Manufacturing
SIC 3716: Motor Homes
Sales Range $50
M
to 100
M
# of Employees 350
Plant Area 286,000
ft2
Annual Production 4,604
units
Production Hrs. Annual 4,160
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $130,072 3,389,062
kWh
Electricity Demand $224,865 11,243
kW-mo/yr
Electricity Fees $1,200 -
Natural Gas $44,385 9,816
MMBtu
TOTAL YEARLY COSTS $400,522
RECOMMENDED SAVINGS* $53,096 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,384

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Primary Raw Material Savings
01 2.7442: Keep doors and windows shut when not on use $11,472 - - - $11,472
-
MMBtu
- -
02 2.7231: Use radiant heater for spot heating $4,443 - $169
4,410
kWh
- $4,274
-
MMBtu
- -
03 2.7224: Reduce space conditioning during non-working hours $573 - - - $573
-
MMBtu
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,218 $360 $885
23,100
kWh
$1,333
-
kW-mo/yr
- - -
05 2.4239: Eliminate or reduce compressed air usage $1,843 - $735
19,199
kWh
$1,108
-
kW-mo/yr
- - -
06 2.4221: Install compressor air intakes in coolest locations $725 $1,500 - - $725
-
MMBtu
- -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $10,730 $31,075 $4,281
111,788
kWh
$6,449
-
kW-mo/yr
- - -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,596 - $1,036
27,048
kWh
$1,560
-
kW-mo/yr
- - -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $18,496 $1,515,645 $5,849
152,716
kWh
$8,811
-
kW-mo/yr
- $2,113 $1,723
TOTAL RECOMMENDED $53,096 $1,548,580 $12,955
338,261
kWh
$19,261
-
kW-mo/yr
$17,044
-
MMBtu
$2,113 $1,723
TOTAL IMPLEMENTED $32,384 $1,515,645 $6,584
171,915
kWh
$9,919
-
kW-mo/yr
$12,045
-
MMBtu
$2,113 $1,723
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs