| Assessment Year | 2016 |
|---|---|
| Principal Product | Injection Molded Plastic Goods |
| NAICS | 326112: Plastics Packaging Film and Sheet (including Laminated) Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
182,000
ft2
|
| Annual Production | 16,725,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $701,910 | 10,516,200 |
kWh
|
$0.067 |
| Electricity Demand | $104,883 | 22,008 |
kW-mo/yr
|
$4.77 |
| Natural Gas | $46,940 | 9,677 |
MMBtu
|
$4.85 |
| TOTAL YEARLY COSTS | $853,733 | |||
| RECOMMENDED SAVINGS* | $65,586 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $23,931 | $14,250 |
$4,539
74,270
kWh
|
$540
-
kW-mo/yr
|
$18,852
-
MMBtu
|
- | |
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $4,308 | - |
$4,308
70,497
kWh
|
- | - | - | |
| 03 | 2.4151: Develop a repair/replace policy | $1,272 | $4,748 |
$1,143
18,706
kWh
|
$129
-
kW-mo/yr
|
- | - | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $4,969 | $23,750 |
$4,466
73,080
kWh
|
$503
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,937 | $1,000 |
$3,610
59,081
kWh
|
$407
-
kW-mo/yr
|
- | $(-1,080.0) | |
| 06 | 2.5123: Reduce fluid flow rates | $5,273 | $1,000 |
$4,739
77,556
kWh
|
$534
-
kW-mo/yr
|
- | - | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,802 | $3,700 |
$4,264
69,781
kWh
|
$538
-
kW-mo/yr
|
- | - | |
| 08 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $18,094 | $103,500 |
$16,262
266,112
kWh
|
$1,832
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $65,586 | $151,948 |
$43,331
709,083
kWh
|
$4,483
-
kW-mo/yr
|
$18,852
-
MMBtu
|
$(-1,080.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs