Assessment Year | 1984 |
---|---|
Principal Product | WOOD VENEER |
NAICS |
n/a
|
SIC | 2435: Hardwood Veneer and Plywood |
Sales Range | $1 M to 5M |
# of Employees | 42 |
Plant Area |
n/a
|
Annual Production | 54,500
thousand feet
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $85,000 | 1,699,883 |
kWh
|
$0.050 |
Wood | $38,400 | 16,512 |
MMBtu
|
$2.33 |
Other Energy | $92,852 | 24,435 |
MMBtu
|
$3.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,593 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,245 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings | Other Energy Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $32,600 | $10,000 | - | - |
$32,600
-
MMBtu
|
- | |
02 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $3,306 | - | - | - |
$3,306
-
MMBtu
|
- | |
03 | 2.1392: Replace purchased steam with other energy source | $4,339 | $10,000 | - |
$(-1,920.0)
-
MMBtu
|
$6,259
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,118 | $3,218 |
$1,755
28,429
kWh
|
- | - | $1,363 | |
05 | 2.4131: Size electric motors for peak operating efficiency | $230 | - |
$230
4,103
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $43,593 | $23,218 |
$1,985
32,532
kWh
|
$(-1,920.0)
-
MMBtu
|
$42,165
-
MMBtu
|
$1,363 | ||
TOTAL IMPLEMENTED | $40,245 | $20,000 | - |
$(-1,920.0)
-
MMBtu
|
$42,165
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs