| Assessment Year | 1984 |
|---|---|
| Principal Product | WOOD VENEER |
| NAICS |
n/a
|
| SIC | 2435: Hardwood Veneer and Plywood |
| Sales Range | $1 M to 5M |
| # of Employees | 42 |
| Plant Area |
n/a
|
| Annual Production | 54,500
thousand feet
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,000 | 1,699,883 |
kWh
|
$0.050 |
| Wood | $38,400 | 16,512 |
MMBtu
|
$2.33 |
| Other Energy | $92,852 | 24,435 |
MMBtu
|
$3.80 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $43,593 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,245 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings | Other Energy Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $32,600 | $10,000 | - | - |
$32,600
-
MMBtu
|
- | |
| 02 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $3,306 | - | - | - |
$3,306
-
MMBtu
|
- | |
| 03 | 2.1392: Replace purchased steam with other energy source | $4,339 | $10,000 | - |
$(-1,920.0)
-
MMBtu
|
$6,259
-
MMBtu
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,118 | $3,218 |
$1,755
28,429
kWh
|
- | - | $1,363 | |
| 05 | 2.4131: Size electric motors for peak operating efficiency | $230 | - |
$230
4,103
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $43,593 | $23,218 |
$1,985
32,532
kWh
|
$(-1,920.0)
-
MMBtu
|
$42,165
-
MMBtu
|
$1,363 | ||
| TOTAL IMPLEMENTED | $40,245 | $20,000 | - |
$(-1,920.0)
-
MMBtu
|
$42,165
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs