ITAC Assessment: UD0938
ITAC logo
ITAC Assessment: UD0938
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product Ice Cream and Beverages
NAICS 311520: Ice Cream and Frozen Dessert Manufacturing
SIC 2024: Ice Cream and Frozen Desserts
Sales Range $100
M
to 500
M
# of Employees 185
Plant Area 145,350
ft2
Annual Production 10,800
Tgal
Production Hrs. Annual 8,400
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $830,458 15,277,101
kWh
Electricity Demand $59,042 32,364
kW-mo/yr
Electricity Fees $78,400 -
Natural Gas $232,989 45,057
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $217,536 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,865

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
01 2.6218: Turn off equipment when not in use $39,463 - - - $39,463
-
MMBtu
- -
02 2.1233: Analyze flue gas for proper air/fuel ratio $3,298 - - - $3,298
-
MMBtu
- -
03 2.3132: Recharge batteries on during off-peak demand periods $1,403 - - $1,403
-
kW-mo/yr
- - -
04 2.4224: Upgrade controls on compressors $107,431 - $99,557
1,984,000
kWh
$7,874
-
kW-mo/yr
- - -
05 2.2621: Modify refrigeration system to operate at a lower pressure $29,938 $3,000 $27,889
555,775
kWh
$2,049
-
kW-mo/yr
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,415 - $1,300
25,911
kWh
$115
-
kW-mo/yr
- - -
07 2.4151: Develop a repair/replace policy $152 $530 $136
2,713
kWh
$16
-
kW-mo/yr
- - -
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,596 $20,100 $4,341
86,500
kWh
$255
-
kW-mo/yr
- - -
09 2.7232: Replace existing hvac unit with high efficiency model $807 $3,133 $1,054
21,000
kWh
$125
-
kW-mo/yr
$(-372.0)
-
MMBtu
- -
10 2.4221: Install compressor air intakes in coolest locations $1,880 $15,000 $1,774
35,362
kWh
$106
-
kW-mo/yr
- - -
11 3.4151: Minimize water usage $27,153 $9,300 $(-410.0)
(-8,169)
kWh
$(-23.0)
-
kW-mo/yr
- $27,320
-
Tgal
$266
-
Tgal
TOTAL RECOMMENDED $217,536 $51,063 $135,641
2,703,092
kWh
$11,920
-
kW-mo/yr
$42,389
-
MMBtu
$27,320
-
Tgal
$266
-
Tgal
TOTAL IMPLEMENTED $4,865 $530 $1,436
28,624
kWh
$131
-
kW-mo/yr
$3,298
-
MMBtu
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs