Assessment Year | 2015 |
---|---|
Principal Product | Medical, Dental and Animal Health Equipment |
NAICS | 339113: Surgical Appliance and Supplies Manufacturing |
SIC | 2599: Furniture and Fixtures, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 460 |
Plant Area |
145,800
ft2
|
Annual Production | 740,479
units
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $212,587 | 5,479,894 |
kWh
|
$0.039 |
Electricity Demand | $188,520 | 14,244 |
kW-mo/yr
|
$13.24 |
Natural Gas | $320,537 | 39,288 |
MMBtu
|
$8.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $133,592 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $56,140 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,757 | - |
$684
22,783
kWh
|
$1,073
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $9,792 | - | - | - |
$9,792
-
MMBtu
|
- | - | - | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $1,936 | $50 |
$1,056
35,140
kWh
|
$880
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $29,266 | $9,200 |
$10,557
351,437
kWh
|
$18,709
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4226: Use / purchase optimum sized compressor | $36,602 | $22,000 |
$16,859
561,204
kWh
|
$19,743
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $3,496 | $2,295 |
$(-25.0)
(-836)
kWh
|
$(-42.0)
-
kW-mo/yr
|
$3,563
-
MMBtu
|
- | - | - | |
07 | 2.6212: Turn off equipment during breaks, reduce operating time | $11,674 | - |
$11,674
388,620
kWh
|
- | - | - | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,715 | - |
$791
26,316
kWh
|
$924
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.4113: Install motor voltage controller on lightly loaded motors | $4,591 | $4,300 |
$1,721
57,287
kWh
|
$2,870
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $2,652 | $5,000 | - | - |
$2,652
-
MMBtu
|
- | - | - | |
11 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $242 | $700 |
$242
8,042
kWh
|
- | - | - | - | - | |
12 | 3.1182: Make a new by-product | $24,789 | $46,000 |
$(-185.0)
(-6,160)
kWh
|
- |
$5,914
-
MMBtu
|
- | $19,060 | - | |
13 | 3.4133: Clean fouling from water lines regularly | $5,080 | $2,750 |
$(-71.0)
(-2,367)
kWh
|
$(-126.0)
-
kW-mo/yr
|
- |
$2,441
-
Tgal
|
- |
$2,836
-
Tgal
|
|
TOTAL RECOMMENDED | $133,592 | $92,295 |
$43,303
1,441,466
kWh
|
$44,031
-
kW-mo/yr
|
$21,921
-
MMBtu
|
$2,441
-
Tgal
|
$19,060 |
$2,836
-
Tgal
|
||
TOTAL IMPLEMENTED | $56,140 | $9,250 |
$24,762
824,296
kWh
|
$21,586
-
kW-mo/yr
|
$9,792
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs