| Assessment Year | 2013 |
|---|---|
| Principal Product | Metal Stamping products |
| NAICS | 336370: Motor Vehicle Metal Stamping |
| SIC | 3465: Automotive Stampings |
| Sales Range | $10 M to 50M |
| # of Employees | 58 |
| Plant Area |
63,000
ft2
|
| Annual Production | 14,000,000
pieces
|
| Production Hrs. Annual | 4,940
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $119,778 | 1,954,289 |
kWh
|
$0.061 |
| Electricity Demand | $8,235 | 4,476 |
kW-mo/yr
|
$1.84 |
| Electricity Fees | $28,215 | - |
|
- |
| Natural Gas | $17,831 | 1,822 |
MMBtu
|
$9.79 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,018 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,754 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,100 | - |
$1,100
17,947
kWh
|
- | - | - | |
| 02 | 2.4151: Develop a repair/replace policy | $654 | $460 |
$623
10,164
kWh
|
$31
-
kW-mo/yr
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,448 | $1,000 |
$1,666
27,188
kWh
|
$82
-
kW-mo/yr
|
- | $(-300.0) | |
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,551 | $3,500 | - | - |
$3,551
-
MMBtu
|
- | |
| 05 | 2.7224: Reduce space conditioning during non-working hours | $1,355 | $2,000 | - | - |
$1,355
-
MMBtu
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,219 | $7,254 |
$4,737
77,285
kWh
|
$202
-
kW-mo/yr
|
- | $280 | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,401 | $9,000 |
$4,066
66,344
kWh
|
$199
-
kW-mo/yr
|
- | $136 | |
| 08 | 2.7135: Install occupancy sensors | $1,290 | $1,400 |
$1,254
20,465
kWh
|
- | - | $36 | |
| TOTAL RECOMMENDED | $19,018 | $24,614 |
$13,446
219,393
kWh
|
$514
-
kW-mo/yr
|
$4,906
-
MMBtu
|
$152 | ||
| TOTAL IMPLEMENTED | $1,754 | $460 |
$1,723
28,111
kWh
|
$31
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs