Assessment Year | 2005 |
---|---|
Principal Product | Automotive Lifts |
NAICS | 333921: Elevator and Moving Stairway Manufacturing |
SIC | 3534: Elevators and Moving Stairways |
Sales Range | $100 M to 500M |
# of Employees | 450 |
Plant Area |
170,000
ft2
|
Annual Production | 28,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $138,086 | 7,485,098 |
kWh
|
$0.018 |
Electricity Demand | $268,541 | 19,056 |
kW-mo/yr
|
$14.09 |
Natural Gas | $371,568 | 43,853 |
MMBtu
|
$8.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $152,299 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $33,798 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3511: Use plant owned transformers or lease transformers | $59,198 | $30,000 | - | - |
$59,198
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $33,240 | $102,000 |
$14,380
846,000
kWh
|
$17,210
-
kW-mo/yr
|
- | $1,650 | |
03 | 2.7134: Use photocell controls | $16,400 | - | - | - |
$16,400
-
MMBtu
|
- | |
04 | 2.2511: Insulate bare equipment | $13,563 | $6,505 | - | - |
$13,563
-
MMBtu
|
- | |
05 | 2.7262: Separate controls of air handlers from ac/ heating systems | $9,550 | $530 | - | - |
$9,550
-
MMBtu
|
- | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $6,922 | $4,800 |
$1,800
90,000
kWh
|
$5,122
-
kW-mo/yr
|
- | - | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,199 | $7,500 |
$784
39,200
kWh
|
$3,415
-
kW-mo/yr
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,477 | - |
$1,565
93,825
kWh
|
$1,912
-
kW-mo/yr
|
- | - | |
09 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $3,364 | - |
$1,530
90,000
kWh
|
$1,834
-
kW-mo/yr
|
- | - | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,915 | - |
$778
45,800
kWh
|
$1,137
-
kW-mo/yr
|
- | - | |
11 | 2.4221: Install compressor air intakes in coolest locations | $471 | $880 |
$175
10,313
kWh
|
$296
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $152,299 | $152,215 |
$21,012
1,215,138
kWh
|
$30,926
-
kW-mo/yr
|
$98,711
-
MMBtu
|
$1,650 | ||
TOTAL IMPLEMENTED | $33,798 | $7,385 |
$1,705
100,313
kWh
|
$2,130
-
kW-mo/yr
|
$29,963
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs