Assessment Year | 2001 |
---|---|
Principal Product | Pressure senstive flexographic printing on labels, tapes and |
NAICS |
n/a
|
SIC | 2672: Coated and Laminated Paper, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
35,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,878 | 1,201,200 |
kWh
|
$0.029 |
Electricity Demand | $43,040 | 2,952 |
kW-mo/yr
|
$14.58 |
Natural Gas | $10,910 | 1,264 |
MMBtu
|
$8.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $71,499 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,635 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.611: Begin a practice of predictive / preventative maintenance | $49,350 | $4,680 | - | - | - | $49,350 | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,653 | - |
$1,404
45,000
kWh
|
$5,249
-
kW-mo/yr
|
- | - | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $3,326 | $1,000 |
$702
22,500
kWh
|
$2,624
-
kW-mo/yr
|
- | - | |
04 | 2.6122: Adjust vents to minimize energy use | $2,451 | $112 |
$232
5,158
kWh
|
$87
-
kW-mo/yr
|
$2,132
-
MMBtu
|
- | |
05 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $2,173 | $364 |
$1,123
36,000
kWh
|
$1,050
-
kW-mo/yr
|
- | - | |
06 | 2.7444: Close holes and openings in building such as broken windows | $2,158 | $1,050 | - | - |
$2,158
-
MMBtu
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,847 | $42 |
$955
30,600
kWh
|
$892
-
kW-mo/yr
|
- | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $1,587 | $423 |
$187
6,000
kWh
|
$1,400
-
kW-mo/yr
|
- | - | |
09 | 2.5122: Replace high resistance ducts, pipes, and fittings | $860 | $250 |
$265
8,500
kWh
|
$595
-
kW-mo/yr
|
- | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $580 | $2,526 |
$300
9,600
kWh
|
$280
-
kW-mo/yr
|
- | - | |
11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $514 | - |
$266
8,520
kWh
|
$248
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $71,499 | $10,447 |
$5,434
171,878
kWh
|
$12,425
-
kW-mo/yr
|
$4,290
-
MMBtu
|
$49,350 | ||
TOTAL IMPLEMENTED | $21,635 | $5,767 |
$5,168
163,358
kWh
|
$12,177
-
kW-mo/yr
|
$4,290
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs