| Assessment Year | 1991 |
|---|---|
| Principal Product | ENVELOPES |
| NAICS |
n/a
|
| SIC | 2677: Envelopes |
| Sales Range | $1 M to 5M |
| # of Employees | 220 |
| Plant Area |
n/a
|
| Annual Production | 750,000,000
pieces
|
| Production Hrs. Annual | 6,640
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $226,483 | 4,946,952 |
kWh
|
$0.046 |
| Natural Gas | $8,362 | 1,929 |
MMBtu
|
$4.33 |
| LPG | $2,103 | 175 |
MMBtu
|
$12.02 |
| Other Energy | $12,126 | 1,219 |
MMBtu
|
$9.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,399 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $2,222 | $3,000 |
$2,222
-
kWh
|
- | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,311 | $1,500 |
$1,311
56,272
kWh
|
- | - | |
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $4,426 | $7,600 | - |
$4,426
-
MMBtu
|
- | |
| 04 | 2.6232: Install set-back timers | $5,440 | - |
$4,427
189,918
kWh
|
- | $1,013 | |
| TOTAL RECOMMENDED | $13,399 | $12,100 |
$7,960
246,190
kWh
|
$4,426
-
MMBtu
|
$1,013 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs