| Assessment Year | 1991 |
|---|---|
| Principal Product | BUSINESS FORMS |
| NAICS |
n/a
|
| SIC | 2761: Manifold Business Forms |
| Sales Range | $5 M to 10M |
| # of Employees | 140 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,600
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $80,663 | 1,467,175 |
kWh
|
$0.055 |
| LPG | $6,461 | 930 |
MMBtu
|
$6.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,773 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $494 | - |
$431
15,533
kWh
|
- | $63 | |
| 02 | 2.7261: Install timers and/or thermostats | $2,837 | $20,000 |
$1,166
21,102
kWh
|
$1,671
-
MMBtu
|
- | |
| 03 | 2.7261: Install timers and/or thermostats | $442 | $20,000 |
$442
16,120
kWh
|
- | - | |
| TOTAL RECOMMENDED | $3,773 | $40,000 |
$2,039
52,755
kWh
|
$1,671
-
MMBtu
|
$63 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs