| Assessment Year | 2026 |
|---|---|
| Principal Product | Custom precision machined parts and complete machines |
| NAICS | 333514: Special Die and Tool, Die Set, Jig, and Fixture Manufacturing |
| SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
| Sales Range | $5 M to 10M |
| # of Employees | 37 |
| Plant Area |
100,000
ft2
|
| Annual Production | 1,000,000
units
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $82,907 | 408,758 |
kWh
|
$0.20 |
| Electricity Demand | $27,067 | 1,752 |
kW-mo/yr
|
$15.45 |
| Electricity Fees | $1,700 | - |
|
- |
| Natural Gas | $75,633 | 4,815 |
MMBtu
|
$15.71 |
| TOTAL YEARLY COSTS | $187,308 | |||
| RECOMMENDED SAVINGS* | $1,351,098 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $732 | $2,589 | - | - | $732 | - | - | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $3,758 | $23,500 |
$4,378
21,590
kWh
|
$(-620.0)
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,962 | $1,575 |
$1,714
8,455
kWh
|
$248
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $4,087 | $1,538 |
$3,590
17,702
kWh
|
$497
-
kW-mo/yr
|
- | - | - | |
| 05 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $1,404 | $150 |
$1,715
8,455
kWh
|
$249
-
kW-mo/yr
|
- | - | $(-560.0) | |
| 06 | 2.2437: Recover waste heat from equipment | $2,451 | $4,000 | - | - | - |
$2,451
-
MMBtu
|
- | |
| 07 | 2.7444: Close holes and openings in building such as broken windows | $11,814 | $19,000 | - | - | - |
$11,814
-
MMBtu
|
- | |
| 08 | 2.7134: Use photocell controls | $344 | $945 |
$317
1,451
kWh
|
$27
-
kW-mo/yr
|
- | - | - | |
| 09 | 2.7124: Make a practice of turning off lights when not needed | $617 | - |
$470
2,321
kWh
|
$147
-
kW-mo/yr
|
- | - | - | |
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $730 | $2,800 |
$558
2,750
kWh
|
$172
-
kW-mo/yr
|
- | - | - | |
| 11 | 2.7261: Install timers and/or thermostats | $5,903 | $2,000 |
$263
1,298
kWh
|
- | - |
$5,640
-
MMBtu
|
- | |
| 12 | 2.7211: Clean and maintain refrigerant condensers and towers | $17,918 | $1,625 |
$17,867
88,101
kWh
|
$51
-
kW-mo/yr
|
- | - | - | |
| 13 | 4.611: Begin a practice of predictive / preventative maintenance | $1,859 | $7,400 |
$1,859
9,166
kWh
|
- | - | - | - | |
| 14 | 2.9114: Use solar heat to make electricty | $4,817 | $600 |
$4,817
23,753
kWh
|
- | - | - | - | |
| 15 | 2.9114: Use solar heat to make electricty | $192,702 | $652,725 |
$192,702
315,789
kWh
|
- | - | - | - | |
| 16 | 4.521: Clear and rent existing space | $1,100,000 | $3,727,100 | - | - | - | - | $1,100,000 | |
| TOTAL RECOMMENDED | $1,351,098 | $4,447,547 |
$230,250
500,831
kWh
|
$771
-
kW-mo/yr
|
$732 |
$19,905
-
MMBtu
|
$1,099,440 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs