Assessment Year | 2025 |
---|---|
Principal Product | Precision plating |
NAICS | 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring |
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $10 M to 50M |
# of Employees | 113 |
Plant Area |
92,856
ft2
|
Annual Production | 81,550,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Rhode Island |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $612,568 | 8,140,347 |
kWh
|
$0.075 |
Electricity Demand | $112,369 | 13,972 |
kW-mo/yr
|
$8.04 |
Electricity Fees | $4,635 | - |
|
- |
Natural Gas | $288,043 | 59,951 |
MMBtu
|
$4.80 |
TOTAL YEARLY COSTS | $1,017,615 | |||
RECOMMENDED SAVINGS* | $48,163 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8123: Pay utility bills on time | $984 | - | - | - | $984 | - | |
02 | 2.9114: Use solar heat to make electricty | $26,200 | $343,027 |
$32,272
403,397
kWh
|
- | - | $(-6,072.0) | |
03 | 2.4221: Install compressor air intakes in coolest locations | $4,144 | $1,950 |
$3,642
45,531
kWh
|
$501
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $273 | $113 |
$240
3,004
kWh
|
$33
-
kW-mo/yr
|
- | - | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $7,585 | $50 |
$7,585
94,813
kWh
|
- | - | - | |
06 | 2.4226: Use / purchase optimum sized compressor | $8,976 | $24,000 |
$7,827
97,843
kWh
|
$1,149
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $48,163 | $369,141 |
$51,567
644,588
kWh
|
$1,683
-
kW-mo/yr
|
$984 | $(-6,072.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs