| Assessment Year | 2023 |
|---|---|
| Principal Product | Glassware |
| NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
| SIC | 3231: Glass Products, Made of Purchased Glass |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
24,000
ft2
|
| Annual Production | 10,000
units
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $96,699 | 319,951 |
kWh
|
$0.30 |
| Natural Gas | $3,838 | 174 |
MMBtu
|
$22.08 |
| TOTAL YEARLY COSTS | $100,537 | |||
| RECOMMENDED SAVINGS* | $60,354 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $60,354 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $57,369 | $319,999 |
$49,582
164,055
kWh
|
$7,787 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $103 | $218 |
$103
342
kWh
|
- | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,596 | $5,020 |
$1,596
5,282
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $326 | $20 |
$326
1,078
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $960 | $2,889 |
$960
3,176
kWh
|
- | |
| TOTAL RECOMMENDED | $60,354 | $328,146 |
$52,567
173,933
kWh
|
$7,787 | ||
| TOTAL IMPLEMENTED | $60,354 | $328,146 |
$52,567
173,933
kWh
|
$7,787 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs