| Assessment Year | 2024 |
|---|---|
| Principal Product | Plastic membranes and films |
| NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $100 M to 500M |
| # of Employees | 70 |
| Plant Area |
73,500
ft2
|
| Annual Production | 150,000,000
units
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $1,219,510 | 11,747,534 |
kWh
|
$0.10 | |
| Electricity Demand | $790,819 | 32,091 |
kW-mo/yr
|
$24.64 | |
| Electricity Fees | $13,715 | - |
|
- | |
| Natural Gas | $149,927 | 16,361 |
MMBtu
|
$9.16 | |
| Waste Disposal Costs | |||||
| Water Usage | $54,046 | 2,461 |
Tgal
|
$21.96 | |
| TOTAL YEARLY COSTS | $2,228,018 | ||||
| RECOMMENDED SAVINGS* | $51,535 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8123: Pay utility bills on time | $299 | - | - | - | $299 | - | |
| 02 | 2.3212: Optimize plant power factor | $3,906 | $30,482 | - |
$3,906
-
kW-mo/yr
|
- | - | |
| 03 | 2.6231: Utilize controls to operate equipment only when needed | $1,826 | $30 |
$1,826
17,590
kWh
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,198 | $1,300 |
$6,941
66,870
kWh
|
$2,257
-
kW-mo/yr
|
- | - | |
| 05 | 2.9114: Use solar heat to make electricty | $30,199 | $266,755 |
$30,199
290,939
kWh
|
- | - | - | |
| 06 | 2.7261: Install timers and/or thermostats | $1,409 | $1,997 |
$179
1,720
kWh
|
- | - |
$1,231
-
MMBtu
|
|
| 07 | 2.7232: Replace existing hvac unit with high efficiency model | $4,288 | $31,098 |
$3,236
31,175
kWh
|
$1,052
-
kW-mo/yr
|
- | - | |
| 08 | 2.2511: Insulate bare equipment | $410 | $1,310 | - | - | - |
$410
-
MMBtu
|
|
| TOTAL RECOMMENDED | $51,535 | $332,972 |
$42,381
408,294
kWh
|
$7,215
-
kW-mo/yr
|
$299 |
$1,641
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs