| Assessment Year | 2026 |
|---|---|
| Principal Product | Tractor Attatchments |
| NAICS | 333111: Farm Machinery and Equipment Manufacturing |
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 230 |
| Plant Area |
530,000
ft2
|
| Annual Production | 20,000
units
|
| Production Hrs. Annual | 7,350
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $670,780 | 7,869,685 |
kWh
|
$0.085 |
| Electricity Demand | $83,684 | 19,554 |
kW-mo/yr
|
$4.28 |
| Electricity Fees | $39,707 | - |
|
- |
| Natural Gas | $870,140 | 84,180 |
MMBtu
|
$10.34 |
| TOTAL YEARLY COSTS | $1,664,311 | |||
| RECOMMENDED SAVINGS* | $163,386 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $362 | $428 |
$318
3,727
kWh
|
$26
-
kW-mo/yr
|
$18 | - | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,891 | $11,280 |
$2,545
29,870
kWh
|
$201
-
kW-mo/yr
|
$145 | - | |
| 03 | 2.7135: Install occupancy sensors | $13,768 | $1,357 |
$13,080
153,527
kWh
|
- | $688 | - | |
| 04 | 2.7135: Install occupancy sensors | $4,983 | $1,507 |
$4,734
55,566
kWh
|
- | $249 | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $30,043 | $25,158 |
$25,940
304,463
kWh
|
$2,602
-
kW-mo/yr
|
$1,501 | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $12,379 | $250 |
$10,455
122,711
kWh
|
$1,305
-
kW-mo/yr
|
$619 | - | |
| 07 | 2.4226: Use / purchase optimum sized compressor | $54,343 | $127,816 |
$51,627
605,955
kWh
|
- | $2,716 | - | |
| 08 | 2.7261: Install timers and/or thermostats | $1,137 | $1,281 |
$1,080
12,671
kWh
|
- | $57 | - | |
| 09 | 2.7232: Replace existing hvac unit with high efficiency model | $16,188 | $13,173 |
$13,611
159,748
kWh
|
$1,768
-
kW-mo/yr
|
$809 | - | |
| 10 | 2.7492: Use proper thickness of insulation on building envelope | $20,881 | $16,645 |
$19,838
232,843
kWh
|
- | $1,043 | - | |
| 11 | 2.2511: Insulate bare equipment | $6,411 | $14,900 | - | - | - |
$6,411
-
MMBtu
|
|
| TOTAL RECOMMENDED | $163,386 | $213,795 |
$143,228
1,681,081
kWh
|
$5,902
-
kW-mo/yr
|
$7,845 |
$6,411
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||