Assessment Year 2025
Principal Product Metal Vehicle Parts
NAICS 336370: Motor Vehicle Metal Stamping
SIC 3465: Automotive Stampings
Sales Range $100
M
to 500
M
# of Employees 582
Plant Area 698,991
ft2
Annual Production 12,000,000
units
Production Hrs. Annual 6,288
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,531,139 32,418,974
kWh
Electricity Demand $367,500 62,308
kW-mo/yr
Electricity Fees $75,888 -
Natural Gas $198,501 12,102
MMBtu
TOTAL YEARLY COSTS $3,173,028
RECOMMENDED SAVINGS* $1,933,333 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7492: Use proper thickness of insulation on building envelope $325,791 $656,120 $317,473
4,064,959
kWh
- $8,318
02 2.7241: Install outside air damper / economizer on hvac unit $135,884 $7,000 $132,415
1,695,454
kWh
- $3,469
03 2.7232: Replace existing hvac unit with high efficiency model $264,212 $1,445,408 $253,047
3,240,035
kWh
$4,419
-
kW-mo/yr
$6,746
04 2.7243: Improve air circulation with destratification fans / other methods $2,516 $17,050 $2,452
31,399
kWh
- $64
05 2.7261: Install timers and/or thermostats $10,419 $395 $10,153
130,003
kWh
- $266
06 2.7442: Keep doors and windows shut when not on use $17,760 $3,128 $17,307
221,597
kWh
- $453
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $39,620 $5,802 $37,261
477,103
kWh
$1,347
-
kW-mo/yr
$1,012
08 2.9114: Use solar heat to make electricty $1,068,159 $16,699,440 $1,016,468
13,014,961
kWh
$24,420
-
kW-mo/yr
$27,271
09 2.8114: Change rate schedules or other changes in utility service $68,972 $800 - $67,211
-
kW-mo/yr
$1,761
TOTAL RECOMMENDED $1,933,333 $18,835,143 $1,786,576
22,875,511
kWh
$97,397
-
kW-mo/yr
$49,360
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs