Assessment Year | 2025 |
---|---|
Principal Product | Kitchen Cabinets |
NAICS | 337110: Wood Kitchen Cabinet and Countertop Manufacturing |
SIC | 2434: Wood Kitchen Cabinets |
Sales Range | $1 M to 5M |
# of Employees | 525 |
Plant Area |
507,150
ft2
|
Annual Production | 230,000
units
|
Production Hrs. Annual | 2,625
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $970,749 | 7,248,260 |
kWh
|
$0.13 |
Electricity Demand | $51,680 | 10,903 |
kW-mo/yr
|
$4.74 |
Electricity Fees | $74,829 | - |
|
- |
Natural Gas | $309,542 | 31,100 |
MMBtu
|
$9.95 |
TOTAL YEARLY COSTS | $1,406,800 | |||
RECOMMENDED SAVINGS* | $673,991 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $557,887 | $5,002,920 |
$515,280
3,942,461
kWh
|
$4,555
-
kW-mo/yr
|
$38,052 | - | |
02 | 2.3212: Optimize plant power factor | $6,398 | $1,977 | - |
$5,962
-
kW-mo/yr
|
$436 | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $7,813 | $20,150 |
$7,280
55,703
kWh
|
- | $533 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $27,681 | $7,744 |
$20,342
155,641
kWh
|
$5,451
-
kW-mo/yr
|
$1,888 | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $19,072 | $804 |
$12,585
96,287
kWh
|
$5,186
-
kW-mo/yr
|
$1,301 | - | |
06 | 2.4224: Upgrade controls on compressors | $15,539 | $2,872 |
$9,891
75,678
kWh
|
$4,588
-
kW-mo/yr
|
$1,060 | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $24,457 | $7,761 |
$20,377
155,904
kWh
|
$2,412
-
kW-mo/yr
|
$1,668 | - | |
08 | 2.7261: Install timers and/or thermostats | $2,303 | $886 |
$2,145
16,420
kWh
|
- | $158 | - | |
09 | 2.7231: Use radiant heater for spot heating | $6,438 | $20,795 | - | - | - |
$6,438
-
MMBtu
|
|
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,652 | $12,707 |
$1,995
15,263
kWh
|
$1,408
-
kW-mo/yr
|
$249 | - | |
11 | 2.7135: Install occupancy sensors | $2,751 | $2,642 |
$2,563
19,613
kWh
|
- | $188 | - | |
TOTAL RECOMMENDED | $673,991 | $5,081,258 |
$592,458
4,532,970
kWh
|
$29,562
-
kW-mo/yr
|
$45,533 |
$6,438
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs