Assessment Year | 2016 |
---|---|
Principal Product | Office Furniture |
NAICS | 337214: Office Furniture (except Wood) Manufacturing |
SIC | 2522: Office Furniture, Except Wood |
Sales Range | greater than $500 M |
# of Employees | 895 |
Plant Area |
889,425
ft2
|
Annual Production | 339,843
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,591,161 | 25,473,600 |
kWh
|
$0.062 |
Electricity Demand | $1,076,720 | 55,760 |
kW-mo/yr
|
$19.31 |
Electricity Fees | $(-337,970.0) | - |
|
- |
Natural Gas | $1,018,754 | 117,706 |
MMBtu
|
$8.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $669,972 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $283,308 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2425: Use flue gases to heat process or service water | $226,961 | $70,000 | - | - | - |
$226,961
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $148,298 | $25,908 |
$106,652
1,707,525
kWh
|
$63,414
-
kW-mo/yr
|
$(-21,768.0) | - | |
03 | 2.7134: Use photocell controls | $5,176 | $8,087 |
$5,936
95,040
kWh
|
- | $(-760.0) | - | |
04 | 2.7135: Install occupancy sensors | $3,524 | $11,746 |
$4,041
64,696
kWh
|
- | $(-517.0) | - | |
05 | 2.4226: Use / purchase optimum sized compressor | $74,344 | $60,000 |
$58,918
943,290
kWh
|
$26,339
-
kW-mo/yr
|
$(-10,913.0) | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $33,548 | $2,995 |
$18,660
298,745
kWh
|
$19,812
-
kW-mo/yr
|
$(-4,924.0) | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $16,549 | $700 |
$11,891
190,385
kWh
|
$7,087
-
kW-mo/yr
|
$(-2,429.0) | - | |
08 | 2.7261: Install timers and/or thermostats | $155,322 | $3,450 |
$5,417
86,729
kWh
|
- | $(-69.0) |
$149,974
-
MMBtu
|
|
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,250 | $1,800 |
$4,310
69,012
kWh
|
$2,858
-
kW-mo/yr
|
$(-918.0) | - | |
TOTAL RECOMMENDED | $669,972 | $184,686 |
$215,825
3,455,422
kWh
|
$119,510
-
kW-mo/yr
|
$(-42,298.0) |
$376,935
-
MMBtu
|
||
TOTAL IMPLEMENTED | $283,308 | $75,495 |
$34,861
558,142
kWh
|
$29,757
-
kW-mo/yr
|
$(-8,271.0) |
$226,961
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs