Assessment Year | 2016 |
---|---|
Principal Product | Plastic Fuel Tanks |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 71 |
Plant Area |
216,000
ft2
|
Annual Production | 339,843
pieces
|
Production Hrs. Annual | 6,300
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $274,013 | 6,697,620 |
kWh
|
$0.041 |
Electricity Demand | $43,426 | 9,450 |
kW-mo/yr
|
$4.60 |
Electricity Fees | $116,493 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $136,079 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,033 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7241: Install outside air damper / economizer on hvac unit | $61,044 | $120 |
$49,012
1,198,049
kWh
|
- | $12,032 | |
02 | 2.4226: Use / purchase optimum sized compressor | $19,730 | $50,000 |
$14,694
359,188
kWh
|
$1,147
-
kW-mo/yr
|
$3,889 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $24,633 | $100 |
$15,119
369,578
kWh
|
$4,757
-
kW-mo/yr
|
$4,757 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,924 | $2,995 |
$2,436
59,550
kWh
|
$397
-
kW-mo/yr
|
$91 | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $9,574 | - |
$7,687
187,901
kWh
|
- | $1,887 | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,826 | $2,520 |
$3,051
74,576
kWh
|
$1,627
-
kW-mo/yr
|
$1,148 | |
07 | 2.2511: Insulate bare equipment | $7,261 | $5,208 |
$4,801
117,346
kWh
|
$1,029
-
kW-mo/yr
|
$1,431 | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,480 | $15,842 |
$2,963
72,433
kWh
|
$634
-
kW-mo/yr
|
$883 | |
09 | 2.7134: Use photocell controls | $607 | $582 |
$487
11,906
kWh
|
- | $120 | |
TOTAL RECOMMENDED | $136,079 | $77,367 |
$100,250
2,450,527
kWh
|
$9,591
-
kW-mo/yr
|
$26,238 | ||
TOTAL IMPLEMENTED | $40,033 | $2,620 |
$25,857
632,055
kWh
|
$6,384
-
kW-mo/yr
|
$7,792 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs