ITAC Assessment: UA0155
ITAC logo
ITAC Assessment: UA0155
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Plastic Fuel Tanks
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 71
Plant Area 216,000
ft2
Annual Production 339,843
pieces
Production Hrs. Annual 6,300
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $274,013 6,697,620
kWh
Electricity Demand $43,426 9,450
kW-mo/yr
Electricity Fees $116,493 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $136,079 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $40,033

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7241: Install outside air damper / economizer on hvac unit $61,044 $120 $49,012
1,198,049
kWh
- $12,032
02 2.4226: Use / purchase optimum sized compressor $19,730 $50,000 $14,694
359,188
kWh
$1,147
-
kW-mo/yr
$3,889
03 2.4231: Reduce the pressure of compressed air to the minimum required $24,633 $100 $15,119
369,578
kWh
$4,757
-
kW-mo/yr
$4,757
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,924 $2,995 $2,436
59,550
kWh
$397
-
kW-mo/yr
$91
05 2.6231: Utilize controls to operate equipment only when needed $9,574 - $7,687
187,901
kWh
- $1,887
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $5,826 $2,520 $3,051
74,576
kWh
$1,627
-
kW-mo/yr
$1,148
07 2.2511: Insulate bare equipment $7,261 $5,208 $4,801
117,346
kWh
$1,029
-
kW-mo/yr
$1,431
08 2.7142: Utilize higher efficiency lamps and/or ballasts $4,480 $15,842 $2,963
72,433
kWh
$634
-
kW-mo/yr
$883
09 2.7134: Use photocell controls $607 $582 $487
11,906
kWh
- $120
TOTAL RECOMMENDED $136,079 $77,367 $100,250
2,450,527
kWh
$9,591
-
kW-mo/yr
$26,238
TOTAL IMPLEMENTED $40,033 $2,620 $25,857
632,055
kWh
$6,384
-
kW-mo/yr
$7,792
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings