Assessment Year | 2008 |
---|---|
Principal Product | palletizers |
NAICS | 333993: Packaging Machinery Manufacturing |
SIC | 3565: Packaging Machinery |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
140,000
ft2
|
Annual Production | 50
pieces
|
Production Hrs. Annual | 2,574
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $92,575 | 981,680 |
kWh
|
$0.094 |
Electricity Demand | $17,128 | 4,264 |
kW-mo/yr
|
$4.02 |
Electricity Fees | $485 | - |
|
- |
Natural Gas | $29,339 | 1,785 |
MMBtu
|
$16.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,100 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,435 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,259 | $60,237 |
$11,403
122,092
kWh
|
$2,288
-
kW-mo/yr
|
$568 | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,022 | $15,096 |
$1,594
16,900
kWh
|
$350
-
kW-mo/yr
|
$78 | - | |
03 | 2.7231: Use radiant heater for spot heating | $7,553 | $13,800 | - | - | - |
$7,553
-
MMBtu
|
|
04 | 2.7261: Install timers and/or thermostats | $90 | $236 | - | - | - |
$90
-
MMBtu
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $788 | - |
$788
8,033
kWh
|
- | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $202 | $700 |
$202
2,057
kWh
|
- | - | - | |
07 | 2.4133: Use most efficient type of electric motors | $94 | $327 |
$94
999
kWh
|
- | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $481 | $2,100 |
$379
4,019
kWh
|
$102
-
kW-mo/yr
|
- | - | |
09 | 2.4226: Use / purchase optimum sized compressor | $2,611 | $7,000 |
$2,317
24,573
kWh
|
$294
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $28,100 | $99,496 |
$16,777
178,673
kWh
|
$3,034
-
kW-mo/yr
|
$646 |
$7,643
-
MMBtu
|
||
TOTAL IMPLEMENTED | $27,435 | $96,833 |
$16,304
173,655
kWh
|
$2,932
-
kW-mo/yr
|
$646 |
$7,553
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs