Assessment Year 2008
Principal Product palletizers
NAICS 333993: Packaging Machinery Manufacturing
SIC 3565: Packaging Machinery
Sales Range $10
M
to 50
M
# of Employees 95
Plant Area 140,000
ft2
Annual Production 50
pieces
Production Hrs. Annual 2,574
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $92,575 981,680
kWh
Electricity Demand $17,128 4,264
kW-mo/yr
Electricity Fees $485 -
Natural Gas $29,339 1,785
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,100 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $27,435

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $14,259 $60,237 $11,403
122,092
kWh
$2,288
-
kW-mo/yr
$568 -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,022 $15,096 $1,594
16,900
kWh
$350
-
kW-mo/yr
$78 -
03 2.7231: Use radiant heater for spot heating $7,553 $13,800 - - - $7,553
-
MMBtu
04 2.7261: Install timers and/or thermostats $90 $236 - - - $90
-
MMBtu
05 2.4231: Reduce the pressure of compressed air to the minimum required $788 - $788
8,033
kWh
- - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $202 $700 $202
2,057
kWh
- - -
07 2.4133: Use most efficient type of electric motors $94 $327 $94
999
kWh
- - -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $481 $2,100 $379
4,019
kWh
$102
-
kW-mo/yr
- -
09 2.4226: Use / purchase optimum sized compressor $2,611 $7,000 $2,317
24,573
kWh
$294
-
kW-mo/yr
- -
TOTAL RECOMMENDED $28,100 $99,496 $16,777
178,673
kWh
$3,034
-
kW-mo/yr
$646 $7,643
-
MMBtu
TOTAL IMPLEMENTED $27,435 $96,833 $16,304
173,655
kWh
$2,932
-
kW-mo/yr
$646 $7,553
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs