ITAC Assessment: TT0335
ITAC logo
ITAC Assessment: TT0335
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product CV Flanges, Diff Cases, Diff Lockout Collars, Drive Pinion Forgings, Helical Gears, Input Shafts, Output Gears, Diff Pinions, Side Gears, Spindles
NAICS 332111: Iron and Steel Forging
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $100
M
to 500
M
# of Employees 316
Plant Area 152,050
ft2
Annual Production 10,846,374
pieces
Production Hrs. Annual 8,568
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,687,471 39,774,481
kWh
Electricity Demand $984,499 160,560
kW-mo/yr
Electricity Fees $(-218,572.0) -
Natural Gas $232,406 22,634
MMBtu
Waste Disposal Costs
Water Usage $36,844 16,311
Tgal
Water Disposal $207,944 16,311
Tgal
TOTAL YEARLY COSTS $2,930,592
RECOMMENDED SAVINGS* $418,315 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
01 2.3137: Use power during off-peak periods $1,852 $60 - - - $1,852
02 4.721: Initiate a program to acquire iso certification $78,715 $15,000 $69,186
1,630,754
kWh
$9,529
-
MMBtu
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,409 $1,885 $9,409
221,911
kWh
- - -
04 3.6192: Use a less expensive method of waste removal $263,515 $80,000 $(-30,424.8)
(-835,847)
kWh
- - $293,940
05 2.7447: Install vinyl strip / high speed / air curtain doors $12,543 $4,000 $12,543
298,543
kWh
- - -
06 2.4322: Use or replace with energy efficient substitutes $11,177 $11,250 $11,177
263,619
kWh
- - -
07 3.4116: Meter recycled water (to reduce sewer charges) $4,933 $9,000 - - $4,933
-
Tgal
-
08 2.9114: Use solar heat to make electricty $36,172 $520,500 $36,172
861,260
kWh
- - -
TOTAL RECOMMENDED $418,315 $641,695 $108,063
2,440,240
kWh
$9,529
-
MMBtu
$4,933
-
Tgal
$295,791
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs