Assessment Year | 2013 |
---|---|
Principal Product | plastic containers |
NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 20 |
Plant Area |
60,000
ft2
|
Annual Production | 1,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,279 | 694,480 |
kWh
|
$0.058 |
Electricity Demand | $63,623 | 5,360 |
kW-mo/yr
|
$11.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,006 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,661 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,465 | $100 |
$5,465
94,223
kWh
|
- | - | |
02 | 2.7135: Install occupancy sensors | $2,202 | $2,150 |
$2,202
37,966
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $47 | $75 |
$37
638
kWh
|
$10
-
kW-mo/yr
|
- | |
04 | 2.8112: Combine utility meters | $6,476 | $12,000 | - | - | $6,476 | |
05 | 2.4157: Establish a predictive maintenance program | $4,667 | $9,338 |
$311
5,365
kWh
|
$4,356
-
kW-mo/yr
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,685 | $8,460 |
$1,905
32,856
kWh
|
$780
-
kW-mo/yr
|
- | |
07 | 2.4224: Upgrade controls on compressors | $464 | $800 |
$464
8,026
kWh
|
- | - | |
TOTAL RECOMMENDED | $22,006 | $32,923 |
$10,384
179,074
kWh
|
$5,146
-
kW-mo/yr
|
$6,476 | ||
TOTAL IMPLEMENTED | $8,661 | $9,435 |
$7,871
135,743
kWh
|
$790
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs