Assessment Year | 1995 |
---|---|
Principal Product | Steel Cylinders |
NAICS |
n/a
|
SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
9,000
ft2
|
Annual Production | 100,000
thousand feet
|
Production Hrs. Annual | 6,800
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $61,866 | 975,381 |
kWh
|
$0.063 |
Natural Gas | $20,925 | 7,565 |
MMBtu
|
$2.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,399 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,153 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,906 | $4,500 | - |
$1,906
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,781 | $150 |
$1,781
28,136
kWh
|
- | |
03 | 2.4314: Use synthetic lubricant | $1,712 | $500 |
$1,712
26,964
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $1,153 | $250 | - |
$1,153
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $488 | $97 |
$488
7,620
kWh
|
- | |
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $359 | - |
$359
-
kWh
|
- | |
TOTAL RECOMMENDED | $7,399 | $5,497 |
$4,340
62,720
kWh
|
$3,059
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,153 | $250 | - |
$1,153
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs