Assessment Year | 2012 |
---|---|
Principal Product | Titania-Based Ceramic Catalyst |
NAICS | 325180: Other Basic Inorganic Chemical Manufacturing |
SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
Sales Range | less than $500 k |
# of Employees | 106 |
Plant Area |
131,000
ft2
|
Annual Production | 1,080,003
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $576,284 | 10,471,562 |
kWh
|
$0.055 |
Electricity Demand | $186,381 | 22,993 |
kW-mo/yr
|
$8.11 |
Natural Gas | $158,228 | 39,119 |
MMBtu
|
$4.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $67,687 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,087 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2113: Repair or replace steam traps | $18,416 | $2,040 | - | - |
$18,416
-
MMBtu
|
|
02 | 2.2437: Recover waste heat from equipment | $5,056 | $2,500 | - | - |
$5,056
-
MMBtu
|
|
03 | 2.4224: Upgrade controls on compressors | $1,269 | $50 |
$1,048
19,052
kWh
|
$221
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,171 | $3,000 |
$2,620
47,647
kWh
|
$551
-
kW-mo/yr
|
- | |
05 | 2.6211: Conserve energy by efficient use of vending machines | $298 | $20 |
$248
4,511
kWh
|
$50
-
kW-mo/yr
|
- | |
06 | 2.6218: Turn off equipment when not in use | $1,476 | $736 |
$1,476
26,846
kWh
|
- | - | |
07 | 2.6218: Turn off equipment when not in use | $1,365 | $100 |
$1,054
19,168
kWh
|
$311
-
kW-mo/yr
|
- | |
08 | 2.6231: Utilize controls to operate equipment only when needed | $15,500 | $9,600 |
$15,500
281,870
kWh
|
- | - | |
09 | 2.7111: Reduce illumination to minimum necessary levels | $2,396 | $2,244 |
$1,851
33,660
kWh
|
$545
-
kW-mo/yr
|
- | |
10 | 2.7111: Reduce illumination to minimum necessary levels | $758 | $864 |
$586
10,656
kWh
|
$172
-
kW-mo/yr
|
- | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,678 | $29,400 |
$13,042
237,133
kWh
|
$2,636
-
kW-mo/yr
|
- | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $683 | $683 |
$528
9,612
kWh
|
$155
-
kW-mo/yr
|
- | |
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,621 | $10,640 |
$1,349
24,528
kWh
|
$272
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $67,687 | $61,877 |
$39,302
714,683
kWh
|
$4,913
-
kW-mo/yr
|
$23,472
-
MMBtu
|
||
TOTAL IMPLEMENTED | $37,087 | $14,640 |
$18,120
329,517
kWh
|
$551
-
kW-mo/yr
|
$18,416
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs