Assessment Year 2011
Principal Product Conveyor Assemblies
NAICS 333922: Conveyor and Conveying Equipment Manufacturing
SIC 3535: Conveyors and Conveying Equipment
Sales Range $50
M
to 100
M
# of Employees 530
Plant Area 600,000
ft2
Annual Production 54,432
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $486,882 10,509,800
kWh
Natural Gas $369,849 41,548
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $51,245 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $4,235 - $4,235
91,480
kWh
- -
02 2.2511: Insulate bare equipment $7,025 $2,100 - $7,025
-
MMBtu
-
03 2.4224: Upgrade controls on compressors $1,990 $1,600 $1,990
43,000
kWh
- -
04 2.7241: Install outside air damper / economizer on hvac unit $875 $1,200 $875
18,900
kWh
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $11,337 $21,600 $11,337
244,860
kWh
- -
06 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $1,730 $4,900 $1,730
37,609
kWh
- -
07 2.3212: Optimize plant power factor $6,582 $32,600 - - $6,582
08 2.7425: Clean or color roof to reduce solar load $11,486 $102,000 $11,486
247,689
kWh
- -
09 2.4151: Develop a repair/replace policy $5,985 $1,347 $5,985
129,267
kWh
- -
TOTAL RECOMMENDED $51,245 $167,347 $37,638
812,805
kWh
$7,025
-
MMBtu
$6,582
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs