Assessment Year | 2000 |
---|---|
Principal Product | Refrigerator compressors |
NAICS |
n/a
|
SIC | 3415: |
Sales Range | $50 M to 100M |
# of Employees | 670 |
Plant Area |
330,000
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $823,644 | 35,715,710 |
kWh
|
$0.023 |
Electricity Demand | $416,185 | 66,761 |
kW-mo/yr
|
$6.23 |
Natural Gas | $505,038 | 122,668 |
MMBtu
|
$4.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $664,573 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $321,273 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.611: Begin a practice of predictive / preventative maintenance | $184,000 | $44,000 | - | - | - | - | - | - | - | $184,000 | |
02 | 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system | $182,800 | $173,400 |
$19,200
833,822
kWh
|
$18,000
-
kW-mo/yr
|
- |
$105,200
-
Tgal
|
- |
$40,400
-
Tgal
|
- | - | |
03 | 4.421: Modify current incentive program | $78,500 | $16,450 | - | - | - | - | - | - | - | $78,500 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $68,153 | $6,800 |
$52,902
2,300,117
kWh
|
$15,251
-
kW-mo/yr
|
- | - | - | - | - | - | |
05 | 2.8113: Purchase gas directly from a contract gas supplier | $50,500 | - | - | - | - | - | $50,500 | - | - | - | |
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $35,400 | $18,900 | - |
$35,400
-
kW-mo/yr
|
- | - | - | - | - | - | |
07 | 2.2521: Isolate steam lines to avoid heating air conditioned areas | $31,500 | - | - | - |
$31,500
-
MMBtu
|
- | - | - | - | - | |
08 | 2.4157: Establish a predictive maintenance program | $33,720 | $5,075 |
$15,300
663,540
kWh
|
- | - | - | - | - | $15,300 | $3,120 | |
TOTAL RECOMMENDED | $664,573 | $264,625 |
$87,402
3,797,479
kWh
|
$68,651
-
kW-mo/yr
|
$31,500
-
MMBtu
|
$105,200
-
Tgal
|
$50,500 |
$40,400
-
Tgal
|
$15,300 | $265,620 | ||
TOTAL IMPLEMENTED | $321,273 | $74,775 |
$68,202
2,963,657
kWh
|
$50,651
-
kW-mo/yr
|
- | - | - | - | $15,300 | $187,120 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs