Assessment Year | 1994 |
---|---|
Principal Product | Content Lens Solution and Mouthwash |
NAICS |
n/a
|
SIC | 2834: Pharmaceutical Preparations |
Sales Range | $100 M to 500M |
# of Employees | 433 |
Plant Area |
190,400
ft2
|
Annual Production | 100,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $687,425 | 15,956,038 |
kWh
|
$0.043 |
Natural Gas | $289,723 | 79,753 |
MMBtu
|
$3.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,202 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2163: Use minimum steam operating pressure | $12,830 | - | - |
$12,830
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $2,780 | $2,100 |
$1,941
45,135
kWh
|
$839
-
MMBtu
|
|
03 | 2.4314: Use synthetic lubricant | $2,004 | - |
$2,004
46,600
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,588 | $1,170 |
$1,588
36,928
kWh
|
- | |
TOTAL RECOMMENDED | $19,202 | $3,270 |
$5,533
128,663
kWh
|
$13,669
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs