Assessment Year | 1993 |
---|---|
Principal Product | children's clothing, shorts and pant |
NAICS |
n/a
|
SIC | 2361: Girls', Children's, and Infants' Dresses, Blouses, and Shirts |
Sales Range | $1 M to 5M |
# of Employees | 255 |
Plant Area |
42,421
ft2
|
Annual Production | 3,720,000
pieces
|
Production Hrs. Annual | 2,400
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $60,894 | 1,194,021 |
kWh
|
$0.051 |
Natural Gas | $465 | 67 |
MMBtu
|
$6.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,135 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,135 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7144: Install spectral reflectors / delamp | $7,383 | $26,368 |
$7,383
130,422
kWh
|
- | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $5,037 | - |
$5,037
98,769
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $957 | $1,710 |
$957
18,757
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $643 | $406 |
$643
12,603
kWh
|
- | |
05 | 2.7261: Install timers and/or thermostats | $338 | $840 |
$90
1,758
kWh
|
$248
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $463 | $1,686 |
$463
9,086
kWh
|
- | |
07 | 2.6218: Turn off equipment when not in use | $314 | - |
$314
6,155
kWh
|
- | |
TOTAL RECOMMENDED | $15,135 | $31,010 |
$14,887
277,550
kWh
|
$248
-
MMBtu
|
||
TOTAL IMPLEMENTED | $15,135 | $31,010 |
$14,887
277,550
kWh
|
$248
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs