| Assessment Year | 1993 |
|---|---|
| Principal Product | Aluminum lighting poles and flagpole |
| NAICS |
n/a
|
| SIC | 3354: Aluminum Extruded Products |
| Sales Range | $10 M to 50M |
| # of Employees | 103 |
| Plant Area |
90,000
ft2
|
| Annual Production | 30,000
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $76,032 | 1,617,819 |
kWh
|
$0.047 |
| Natural Gas | $51,575 | 9,048 |
MMBtu
|
$5.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,334 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,951 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $2,736 | $8,900 | - |
$2,736
-
MMBtu
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,218 | $840 |
$2,218
47,186
kWh
|
- | |
| 03 | 2.6218: Turn off equipment when not in use | $2,066 | - |
$2,066
43,962
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $1,474 | $720 |
$1,474
31,360
kWh
|
- | |
| 05 | 2.4314: Use synthetic lubricant | $399 | - |
$399
8,499
kWh
|
- | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $248 | $225 |
$248
5,275
kWh
|
- | |
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $193 | - |
$193
4,103
kWh
|
- | |
| TOTAL RECOMMENDED | $9,334 | $10,685 |
$6,598
140,385
kWh
|
$2,736
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,951 | $1,560 |
$5,951
126,611
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs