Assessment Year 1989
Principal Product PRESSURE GAUGES
NAICS
n/a
SIC 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products
Sales Range $10
M
to 50
M
# of Employees 342
Plant Area
n/a
Annual Production 13,000,000
pieces
Production Hrs. Annual 4,700
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $227,821 4,800,997
kWh
Natural Gas $25,186 5,045
MMBtu
LPG $13,114 3,389
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $19,468 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,698

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings LPG Savings Administrative Changes Savings
01 2.7261: Install timers and/or thermostats $3,618 $3,660 - $240
-
MMBtu
$3,378
-
MMBtu
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,973 $840 $4,973
105,803
kWh
- - -
03 2.7123: Keep lamps and reflectors clean $4,180 $9,149 $4,022
85,580
kWh
- - $158
04 2.4312: Improve lubrication practices $2,011 $600 $2,011
42,790
kWh
- - -
05 2.2511: Insulate bare equipment $1,515 $704 $1,515
32,239
kWh
- - -
06 2.4239: Eliminate or reduce compressed air usage $1,075 $350 $1,075
22,860
kWh
- - -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $813 $1,250 $813
17,292
kWh
- - -
08 2.6232: Install set-back timers $675 - $675
14,361
kWh
- - -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $608 $366 $608
12,896
kWh
- - -
TOTAL RECOMMENDED $19,468 $16,919 $15,692
333,821
kWh
$240
-
MMBtu
$3,378
-
MMBtu
$158
TOTAL IMPLEMENTED $12,698 $6,716 $9,080
193,142
kWh
$240
-
MMBtu
$3,378
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings LPG Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs